Keywords and settings
Settings block
The list below is an overview of all the keywords that can be placed inside the &settings
block. All keywords have a default value, so if these are not specified within the block, then the default value is used.
Keyword | Explanation | Default value |
---|---|---|
DEBUG | Output additional debug statements | 0 |
PRESSURE | The total pressure in the gas phase. If the value if negative, calculate the total pressure from the sum of the starting pressure of the compounds. | -1 |
PRECISION | Amount of significant digits to use in output. | 10 |
USETIMESTAMP | Whether to place the output in a new folder which name is based on the current time stamp. If 0, then all output is placed inside a 'RUN' folder. | 1 |
ORDERS | Whether to calculate the reaction orders. (You need to set KEYCOMPONENTS for this) | 1 |
EACT | Whether to calculate the apparent activation energy. (You need to set KEYCOMPONENTS for this) | 1 |
DRC | Whether to perform a degree of rate control analysis. (You need to set KEYCOMPONENTS for this) | 1 |
TDRC | Whether to perform a thermodynamic degree of rate control analysis. (You need to set KEYCOMPONENTS for this) | 1 |
GNUPLOT | Whether to output GNUPlot-style graphs | 1 |
ORDERSDIFF | Step size used in the linear fitting of reaction orders | 0.2 (Wide: 0.4; Normal: 0.2; Tight: 0.002) |
EACTDIFF | Step size used in the linear fitting of the apparent activation energy | 0.002 (Wide: 0.02; Normal: 0.002; Tight: 0.00002) |
DRCDIFF | Step size used in the linear fitting for the degree of rate control analysis | 0.002 (Wide: 0.02; Normal: 0.002; Tight: 0.00002) |
BOOSTER | Default multiplier used to speed-up reaction rates; sometimes leads to faster convergence towards the steady-state solution | 1.0 |
SOLVERTYPE | Type of integration method to use for solving the system of ordinary differential equations | 1.0 (BDF) |
SOLSTOPTIME | Specificies when the solver should re-evaluate the Jacobian matrix. A value of 1 means at every time step. | 1.0 |
SOLMAXSTEP | Maximum number of internal steps the solver is allowed to take. | 5000 |
SOLTESTFAIL | Maximum number of test failures before the solver gives up | 70 |
SOLCONVFAIL | Maximum number of convergence failures before the solver gives up | 100 |
Graphs block
Inside the graphs block, you can set the colors used in the non-GNUPLOT graphs for specific components. On each line, you place the compound between curly brackets followed by the RGB color code. For example:
&graphs # fix colors for particular compounds {A*} #E74C3D {B*} #F29C1F {C*} #287FB9 {*} #15A086
Selectivity block
Inside the selectivity block, you can specify mole balances on which basis you calculate selectivity and degree of selectivity control graphs. You need to specify a name, a key component and one or more products (typically more than one, else the concept of selectivity is rather trivial).
&selectivity species_balance; {A}; {E},{F}
In the above example, the name of the mole balance block is "species_balance", the keycomponent is A and the products of interest are E and F. A detailed example on how to use this block is explained here.